Macchina per la produzione di diamanti artificiali
Il TR-10800 è un sistema di automazione per il confezionamento/riempimento. Specifiche principali: misurazione della temperatura sul substrato; Tolleranza ±15mm. Il tempo di consegna è di 60 giorni; il prezzo è indicato per configurazione. Certificazioni: documentazione CE su richiesta.
- Modello
- TR-10800
- Temperatura
- misurazione sul substrato
- Tolleranza
- ±15 mm
- Categoria
- Attrezzature per l'automazione
- Tempi di consegna
- 60 giorni
A cosa serve questa piattaforma
Cooling type : Water cooling structure - Sample Desk : Diameter of substrate Φ 80 mm - Temperature measurement on substrate : Infrared Temperature Range 300 — 1400 ℃ +Intelligent AI temperature measurement (double temperature measurement) - Height adjustment : Growth height of sample table can be adjusted by ± 15mm - Expansibility : Growth Platform can be extensible Item.
Termini commerciali
| Preventivo | Prezzo per configurazione: risposta entro 48 ore |
|---|---|
| Tempi di consegna | 60 giorni |
| MOQ | 1 unità |
| Origine | Cina |
| Porto di carico | Shenzen, Cina |
| Incoterm | FOB Shenzhen/CIF su richiesta |
| Pagamento | Deposito del 30%, 70% prima della spedizione |
| Garanzia | 24 mesi standard, 36 mesi facoltativi |
Dettagli del prodotto
Note applicative, disegni costruttivi e video dal file di progettazione TROY: la stessa documentazione fornita con il preventivo.

Diamond Crystal:
Using natural or cultivated diamonds as seed crystals, by simulating the growth environment of natural diamonds, the seed crystals slowly grow up and eventually grow into rough diamonds. Lab-grown diamonds are more environmentally friendly than natural diamonds. The harmful carbon emissions produced by natural diamond mining are 57,000 grams per carat, while lab-grown diamonds only release 0.028 grams per carat. In addition, obtaining 1 carat of natural diamonds requires destroying up to 1,750 tons of soil that cannot be repaired and cannot be cultivated for a long time, while cultivated diamonds cause zero damage to the environment, which is more in line with the purpose of sustainable development.

CVD Diamond Machine Features | |
1.High purity stainless steel cavity, free of silicon pollution | L'attrezzatura è sviluppata in modo indipendente con alto vuoto e alta efficienza. Nessun inquinamento da elementi al quarzo Si |
2.Efficient and stable | L'attrezzatura è stabile, efficiente e raggiunge una produzione continua e stabile 24 ore su 24, 7 giorni su 7. Tasso di guasto molto basso |
3.High growth efficiency | Single furnace output up to 57 pieces (7*7mm) |
4. L'asse Z può essere spostato | Linea dell'asse Z fino a ±15 mm, favorevole alla crescita singola di prodotti di grandi dimensioni |
5. Livello netto elevato dei prodotti fabbricati | Product cleanliness level reaches the VVS level |

Diamond Cutting Tools:

System description: TR-10800, microwave plasma chemical vapor deposition (MPCVD) equipment is the most advanced CVD system. A multi-purpose, high stable medium pressure microwave plasma (MPCVD) integrated long crystal equipment is designed and developed according to the specific requirements of users. it has the characteristics of intelligent growth, advanced performance, perfect function, reasonable structure, convenient use, safe and reliable, beautiful appearance and so on. it is especially suitable for chemical vapor deposition (CVD) of single crystal and polycrystalline diamond films and diamond-like films; surface treatment and modification of materials; growth of low temperature oxides. The diamond deposition system is designed for It is used in the process of large area and high deposition rate.
TR-10800 is the most advanced CVD system mainly used to grow high-quality CVD single crystal diamond products for various industries. The absence of internal electrodes in the resonant cavity of microwave plasma chemical vapor deposition (MPCVD) TR-10800 (e.g. cultivation of diamonds, high-end single-crystal cutters, optical lenses, semiconductor sheets, etc.), which avoids contamination from electrode discharges. It operates in a wide range of pressure, resulting in high plasma density, large area, high stability and no contact with the wall of the vacuum, thus avoiding the contamination of the film by the device wall. With its unique advantages, it has become the most promising high quality diamond film deposition method. The system combines the latest microwave technology with the process of computer control and formula drive, and has high reliability, stable operation and unattended safety interlocking.


NO | Nome | External connection | Specifica | Tipo di interfaccia |
1 | Air inlet-1 | Process gas | Gas supply pressure:≥0.2MPa,Process air intake(H2) | 1/4"VCR(Head, equipment side) |
2 | Air inlet-2 | Gas supply pressure:≥0.2MPa,Process air intake(CH4) | 1/4"VCR(Head, equipment side) | |
3 | Air inlet-3 | Gas supply pressure:≥0.2MPa,Process air intake(O2) | 1/4"VCR(Head, equipment side) | |
4 | Air inlet-4 | Gas supply pressure:≥0.2MPa,Process air intake(N2) | 1/4"VCR(Head, equipment side) | |
5 | Air inlet-5 | Standby | 1/4"VCR(Head, equipment side) | |
6 | Equipment vent | Drain pipe | Client orientation | KF25 |
7 | Standby | |||
8 | Cooling water outlet | Chiller | Pagoda interface:φ19mm | |
9 | Cooling water inlet | Chiller | Temperature:20℃,Gas supply pressure:≥5.0 Kg/cm² | Pagoda interface:φ19mm |
10 | CDA inlet | Compressed dry air | System control air supply pressure:≥0.4MPa | φ8Pneumatic fast plug interface |
Dati tecnici completi
| Modello | TR-10800 |
|---|---|
| Temperatura | misurazione sul substrato |
| Tolleranza | ±15 mm |
| Categoria | Attrezzature per l'automazione |
| Tempi di consegna | 60 giorni |
I valori sono nominali a 20 °C. Scarica la scheda tecnica per i modelli cad, le curve di coppia e le mappe I/O del controller.
Dove corre
Dimensionato e commissionato dagli ingegneri TROY.
Dimensionato e commissionato dagli ingegneri TROY.
Dimensionato e commissionato dagli ingegneri TROY.
Dimensionato e commissionato dagli ingegneri TROY.
Domande dell'acquirente
Quali sono le specifiche principali del TR-10800?
Temperatura: misurazione sul substrato; Tolleranza: ±15mm. Una scheda tecnica completa è disponibile su richiesta.
Qual è il tempo di consegna e il MOQ per il TR-10800?
Il tempo di consegna è di 60 giorni; MOQ è 1 unità.
Qual è il prezzo del TR-10800?
Il prezzo è indicato per configurazione, inclusi strumenti e trasporto, ove applicabile.
Ottieni una proposta di prezzo per TR-10800
Includere la parte, la tariffa target e il porto di destinazione. Un ingegnere, non un chatbot, risponde entro 48 ore.
Stessa categoria
Riempitrice per crema a quattro colori
Sistema universale automatico di alimentazione viti e modulo di serraggio
Macchina automatica per la produzione di panini TRB-140
Recensito da TROY Engineering ·. Le specifiche vengono ricontrollate rispetto alla scheda tecnica del fornitore ad ogni preventivo.