Maschine zur Herstellung künstlicher Diamanten
Der TR-10800 ist ein Automatisierungssystem zum Verpacken/Abfüllen. Wichtige Spezifikationen: Temperaturmessung auf dem Substrat; Toleranz ±15 mm. Die Vorlaufzeit beträgt 60 Tage; Die Preise werden pro Konfiguration angegeben. Zertifizierungen: CE-Dokumentation auf Anfrage.
- Modell
- TR-10800
- Temperatur
- Messung auf Untergrund
- Toleranz
- ±15 mm
- Kategorie
- Automatisierungsausrüstung
- Vorlaufzeit
- 60 Tage
Wofür diese Plattform gedacht ist
Cooling type : Water cooling structure - Sample Desk : Diameter of substrate Φ 80 mm - Temperature measurement on substrate : Infrared Temperature Range 300 — 1400 ℃ +Intelligent AI temperature measurement (double temperature measurement) - Height adjustment : Growth height of sample table can be adjusted by ± 15mm - Expansibility : Growth Platform can be extensible Item.
Handelsbedingungen
| Angebot | Preis pro Konfiguration – Antwort innerhalb von 48 Stunden |
|---|---|
| Vorlaufzeit | 60 Tage |
| Mindestbestellmenge | 1 Einheit |
| Herkunft | China |
| Verladehafen | Shenzhen, China |
| Incoterm | FOB Shenzhen / CIF auf Anfrage |
| Zahlung | 30 % Anzahlung, 70 % vor Versand |
| Garantie | 24 Monate Standard, 36 Monate optional |
Produktdetails
Anwendungshinweise, Konstruktionszeichnungen und Videos aus der TROY-Konstruktionsdatei – dieselbe Dokumentation, die mit dem Angebot geliefert wurde.

Diamond Crystal:
Using natural or cultivated diamonds as seed crystals, by simulating the growth environment of natural diamonds, the seed crystals slowly grow up and eventually grow into rough diamonds. Lab-grown diamonds are more environmentally friendly than natural diamonds. The harmful carbon emissions produced by natural diamond mining are 57,000 grams per carat, while lab-grown diamonds only release 0.028 grams per carat. In addition, obtaining 1 carat of natural diamonds requires destroying up to 1,750 tons of soil that cannot be repaired and cannot be cultivated for a long time, while cultivated diamonds cause zero damage to the environment, which is more in line with the purpose of sustainable development.

CVD Diamond Machine Features | |
1.High purity stainless steel cavity, free of silicon pollution | Die Ausrüstung wird unabhängig mit Hochvakuum und hoher Effizienz entwickelt. Keine Verschmutzung durch Quarz-Si-Elemente |
2.Efficient and stable | Die Ausrüstung ist stabil, effizient und ermöglicht eine kontinuierliche und stabile Produktion rund um die Uhr. Sehr niedrige Fehlerrate |
3.High growth efficiency | Single furnace output up to 57 pieces (7*7mm) |
4. Die Z-Achse kann verschoben werden | Z-Achsenlinie bis zu ±15 mm, förderlich für das Einzelwachstum großer Produkte |
5.Hoher Nettograd der hergestellten Produkte | Product cleanliness level reaches the VVS level |

Diamond Cutting Tools:

System description: TR-10800, microwave plasma chemical vapor deposition (MPCVD) equipment is the most advanced CVD system. A multi-purpose, high stable medium pressure microwave plasma (MPCVD) integrated long crystal equipment is designed and developed according to the specific requirements of users. it has the characteristics of intelligent growth, advanced performance, perfect function, reasonable structure, convenient use, safe and reliable, beautiful appearance and so on. it is especially suitable for chemical vapor deposition (CVD) of single crystal and polycrystalline diamond films and diamond-like films; surface treatment and modification of materials; growth of low temperature oxides. The diamond deposition system is designed for It is used in the process of large area and high deposition rate.
TR-10800 is the most advanced CVD system mainly used to grow high-quality CVD single crystal diamond products for various industries. The absence of internal electrodes in the resonant cavity of microwave plasma chemical vapor deposition (MPCVD) TR-10800 (e.g. cultivation of diamonds, high-end single-crystal cutters, optical lenses, semiconductor sheets, etc.), which avoids contamination from electrode discharges. It operates in a wide range of pressure, resulting in high plasma density, large area, high stability and no contact with the wall of the vacuum, thus avoiding the contamination of the film by the device wall. With its unique advantages, it has become the most promising high quality diamond film deposition method. The system combines the latest microwave technology with the process of computer control and formula drive, and has high reliability, stable operation and unattended safety interlocking.


NO | Name | External connection | Spezifikation | Schnittstellentyp |
1 | Air inlet-1 | Process gas | Gas supply pressure:≥0.2MPa,Process air intake(H2) | 1/4"VCR(Head, equipment side) |
2 | Air inlet-2 | Gas supply pressure:≥0.2MPa,Process air intake(CH4) | 1/4"VCR(Head, equipment side) | |
3 | Air inlet-3 | Gas supply pressure:≥0.2MPa,Process air intake(O2) | 1/4"VCR(Head, equipment side) | |
4 | Air inlet-4 | Gas supply pressure:≥0.2MPa,Process air intake(N2) | 1/4"VCR(Head, equipment side) | |
5 | Air inlet-5 | Standby | 1/4"VCR(Head, equipment side) | |
6 | Equipment vent | Drain pipe | Client orientation | KF25 |
7 | Standby | |||
8 | Cooling water outlet | Chiller | Pagoda interface:φ19mm | |
9 | Cooling water inlet | Chiller | Temperature:20℃,Gas supply pressure:≥5.0 Kg/cm² | Pagoda interface:φ19mm |
10 | CDA inlet | Compressed dry air | System control air supply pressure:≥0.4MPa | φ8Pneumatic fast plug interface |
Vollständige technische Daten
| Modell | TR-10800 |
|---|---|
| Temperatur | Messung auf Untergrund |
| Toleranz | ±15 mm |
| Kategorie | Automatisierungsausrüstung |
| Vorlaufzeit | 60 Tage |
Die Werte sind Nominalwerte bei 20 °C. Laden Sie das Datenblatt für CAD-Modelle, Drehmomentkurven und Controller-I/O-Karten herunter.
Wo es läuft
Dimensionierung und Inbetriebnahme durch TROY-Ingenieure.
Dimensionierung und Inbetriebnahme durch TROY-Ingenieure.
Dimensionierung und Inbetriebnahme durch TROY-Ingenieure.
Dimensionierung und Inbetriebnahme durch TROY-Ingenieure.
Fragen des Käufers
Was sind die wichtigsten Spezifikationen des TR-10800?
Temperatur: Messung am Untergrund; Toleranz: ±15 mm. Ein vollständiges Datenblatt ist auf Anfrage erhältlich.
Was ist die Vorlaufzeit und Mindestbestellmenge für den TR-10800?
Die Vorlaufzeit beträgt 60 Tage; MOQ ist 1 Einheit.
Wie ist der Preis für den TR-10800?
Die Preise werden pro Konfiguration angegeben, einschließlich Werkzeug und Fracht, sofern zutreffend.
Holen Sie sich ein Preisangebot für TR-10800
Geben Sie das Teil, die Zielrate und den Zielport an. Ein Techniker – kein Chatbot – antwortet innerhalb von 48 Stunden.
Gleiche Kategorie
Vierfarben-Cremefüllmaschine
Universelles automatisches Schraubenzuführsystem und Anziehmodul
Automatische Brötchenmaschine TRB-140
Bewertet von TROY Engineering ·. Bei jedem Angebot werden die Spezifikationen erneut anhand des Datenblatts des Lieferanten überprüft.